Complying floor wastes pdf 228 39 kb all metropolitan and regional areas in nsw.
Laundry floor waste regulations nsw.
Bathroom or laundry renovations.
Where the sole function of the floor waste gully is to dispose of water spillage and wash down water a minimum dn 50 riser may be used.
Class 2 3 or class 4 part of a building.
The floor waste gully is therefore not intended to drain the floor surface and does not meet the definition of a floor waste in clause 1 5 8 of as 3740.
Water should not pond on the floor with the exception of residual water remaining due to surface tension.
I m advised it s uncommon to have floor wastes in bathrooms and laundry area 2.
Do floor wastes installed in floors not requiring waterproofing have to have a flange.
There are several things to consider in determining if a floor waste needs to be installed.
State by state regulations.
It is necessary to install floor wastes in bathrooms and laundries if a bathroom or laundry is situated at any level above a sole occupancy unit or a public space.
All metropolitan and regional areas in nsw.
Falls in floor finishes should ensure water exits the area at the floor waste or doorway if that is the designed exit point e g.
Laundry door to exterior.
In a class 2 3 or class 4 part of a building where a bathroom or laundry is located above a sole occupancy unit or public space volume one f1 11.
It s not mandatory to have floor waste in wet areas for class 1 buildings residential homes 3.
In nsw a builder s licence is required for all work exceeding 1000 materials and labour.
Filled ground pdf 218 84 kb all installations in nsw.
4 6 7 floor waste gullies 4 6 7 6 removable grate floor waste gullies shall be installed with an accessible removable grate and have a riser of not less than dn 80 to finished surface level.
Their licence does not include plumbing or electrical work but they are authorised to subcontract plumbing and.
Laundry facilities fp2 2 and p2 4 3 the performance requirements for laundry facilities have been expanded to recognise the need for a building to be provided with facilities for the sanitary disposal of waste water where the water has been used for things such as clothes washing mopping floors and other domestic cleaning processes.
Automatic fire sprinkler system design and installation domestic water supply pdf 191 64 kb all metropolitan and regional areas in nsw.
In the above situations the floor is required by the ncc to be graded to the floor waste to prevent water overflow from penetrating to other occupancies or public spaces in the same building.